0.000 VOLTS MINIMUM INPUT AND 5.000 VOLTS MAXIMUM INPUT
BHTZ
SIGNAL DATA TYPE PER CHANNEL
INPUT CHANNEL ANALOG VOLTAGE
CXCY
PART NAME ASSIGNED BY CONTROLLING AGENCY
"INAVY: MODULE, DATA FORTH 24/8; DWG: MODULE, DATA FORTH 24/8 ANALOG"
FEAT
SPECIAL FEATURES
"ANALOG INPUT: 25 CHANNELS, 0-5V, UPDATE TIME 5MS, RESOLUTION 16 BITS, FUSE 100MA/CHANNEL; 4-20 MA OUTPUT RATING: 8 CHANNELS, UPDATE TIME 5MS, OUTPUT DRIVER PULSE WIDTH MODULATED, PWM FREQUENCY 6.14KHZ, FILTER 3 POLES AT 500MS, RESOLUTION 11 BITS; FAULT LED: ON DURING INITIALIZATION, OFF AFTER POWER-ON SELF TEST"